T1 - Application of a novel percutaneous transluminal mitral commissurotomy technique in deformed mitral valve
AU - Thomas, Tony
AU - Ananthakrishna, Rajiv
AU - Chikkabasavaiah, Nagamani Alur
AU - Basavappa, Ramesh
N1 - Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2011
Y1 - 2011
N2 - A 40-year-old woman, known to suffer from rheumatic heart disease, presented with New York Heart Association class III breathlessness of 6 months duration. Transthoracic echocardiogram revealed severe mitral stenosis with deformed double orifice-like mitral valve and severe interatrial septal bulge. Considering the unfavourable anatomy, a high-risk percutaneous transluminal mitral commissurotomy (PTMC) was planned. Initial septal puncture resulted in pericardial effusion with tamponade, which was effectively managed by pericardiocentesis. After haemodynamic stabilisation and a fresh septal puncture, repeated efforts were made to negotiate the balloon across the deformed valve using the conventional Inoue technique. As the attempts were unsuccessful, the authors planned for over-the-wire (OTW) technique, with which the procedure was accomplished successfully. A technically challenging case of PTMC in the presence of adverse factors is presented herein. OTW technique is a useful alternative in the presence of deformed mitral valve.
AB - A 40-year-old woman, known to suffer from rheumatic heart disease, presented with New York Heart Association class III breathlessness of 6 months duration. Transthoracic echocardiogram revealed severe mitral stenosis with deformed double orifice-like mitral valve and severe interatrial septal bulge. Considering the unfavourable anatomy, a high-risk percutaneous transluminal mitral commissurotomy (PTMC) was planned. Initial septal puncture resulted in pericardial effusion with tamponade, which was effectively managed by pericardiocentesis. After haemodynamic stabilisation and a fresh septal puncture, repeated efforts were made to negotiate the balloon across the deformed valve using the conventional Inoue technique. As the attempts were unsuccessful, the authors planned for over-the-wire (OTW) technique, with which the procedure was accomplished successfully. A technically challenging case of PTMC in the presence of adverse factors is presented herein. OTW technique is a useful alternative in the presence of deformed mitral valve.
UR - http://www.scopus.com/inward/record.url?scp=79959720807&partnerID=8YFLogxK
U2 - 10.1136/bcr.04.2011.4116
DO - 10.1136/bcr.04.2011.4116
M3 - Article
C2 - 22692781
AN - SCOPUS:79959720807
SN - 1757-790X
JO - BMJ Case Reports
JF - BMJ Case Reports
ER -