TY - JOUR
T1 - Comparable low revision rates of stemmed and stemless total anatomic shoulder arthroplasties after exclusion of metal-backed glenoid components
T2 - a collaboration between the Australian and Danish national shoulder arthroplasty registries
AU - Nyring, Marc R.K.
AU - Rasmussen, Jeppe V.
AU - Gill, David R.J.
AU - Harries, Dylan
AU - Olsen, Bo S.
AU - Page, Richard S.
N1 - Publisher Copyright:
© 2024 The Author(s)
PY - 2024
Y1 - 2024
N2 - Background: The stemmed anatomic total shoulder arthroplasty is the gold standard in the treatment of glenohumeral osteoarthritis. However, the use of stemless total shoulder arthroplasties has increased in recent years. The number of revision procedures are relatively low, and therefore it has been recommended that national joint replacement registries should collaborate when comparing revision rates. Therefore, we aimed to compare the revision rates of stemmed and stemless TSA used for the diagnosis of glenohumeral osteoarthritis using data from both the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) and the Danish Shoulder Arthroplasty Registry (DSR). Methods: We included all patients who were registered in the AOANJRR and the DSR from January 1, 2012, to December 2021 with an anatomic total shoulder arthroplasty used for osteoarthritis. Revision for any reason was used as the primary outcome. We used the Kaplan-Meier method to illustrate the cumulative revision rates and a multivariate cox regression model to calculate the hazard ratios. All analyses were performed separately for data from AOANJRR and DSR, and the results were then reported using a qualitative approach. Results: A total of 13,066 arthroplasties from AOANJRR and 2882 arthroplasties from DSR were included. The hazard ratio for revision of stemmed TSA with stemless TSA as reference, adjusted for age and gender, was 1.67 (95% confidence interval [CI] 1.34-2.09, P < .001) in AOANJRR and 0.57 (95% CI 0.36-0.89, P = .014) in DSR. When including glenoid type and fixation, surface bearing (only in AOANJRR), and hospital volume in the cox regression model, the hazard ratio for revision of stemmed TSA compared to stemless TSA was 1.22 (95% CI 0.85-1.75, P = .286) in AOANJRR and 1.50 (95% CI 0.91-2.45, P = .109) in DSR. The adjusted hazard ratio for revision of total shoulder arthroplasties with metal-backed glenoid components compared to all-polyethylene glenoid components was 2.54 (95% CI 1.70-3.79, P < .001) in AOANJRR and 4.1 (95% CI 1.92-8.58, P < .001) in DSR. Conclusion: Based on data from 2 national shoulder arthroplasty registries, we found no significant difference in risk of revision between stemmed and stemless total shoulder arthroplasties after adjusting for the type of glenoid component. We advocate that metal-backed glenoid components should be used with caution and not on a routine basis.
AB - Background: The stemmed anatomic total shoulder arthroplasty is the gold standard in the treatment of glenohumeral osteoarthritis. However, the use of stemless total shoulder arthroplasties has increased in recent years. The number of revision procedures are relatively low, and therefore it has been recommended that national joint replacement registries should collaborate when comparing revision rates. Therefore, we aimed to compare the revision rates of stemmed and stemless TSA used for the diagnosis of glenohumeral osteoarthritis using data from both the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) and the Danish Shoulder Arthroplasty Registry (DSR). Methods: We included all patients who were registered in the AOANJRR and the DSR from January 1, 2012, to December 2021 with an anatomic total shoulder arthroplasty used for osteoarthritis. Revision for any reason was used as the primary outcome. We used the Kaplan-Meier method to illustrate the cumulative revision rates and a multivariate cox regression model to calculate the hazard ratios. All analyses were performed separately for data from AOANJRR and DSR, and the results were then reported using a qualitative approach. Results: A total of 13,066 arthroplasties from AOANJRR and 2882 arthroplasties from DSR were included. The hazard ratio for revision of stemmed TSA with stemless TSA as reference, adjusted for age and gender, was 1.67 (95% confidence interval [CI] 1.34-2.09, P < .001) in AOANJRR and 0.57 (95% CI 0.36-0.89, P = .014) in DSR. When including glenoid type and fixation, surface bearing (only in AOANJRR), and hospital volume in the cox regression model, the hazard ratio for revision of stemmed TSA compared to stemless TSA was 1.22 (95% CI 0.85-1.75, P = .286) in AOANJRR and 1.50 (95% CI 0.91-2.45, P = .109) in DSR. The adjusted hazard ratio for revision of total shoulder arthroplasties with metal-backed glenoid components compared to all-polyethylene glenoid components was 2.54 (95% CI 1.70-3.79, P < .001) in AOANJRR and 4.1 (95% CI 1.92-8.58, P < .001) in DSR. Conclusion: Based on data from 2 national shoulder arthroplasty registries, we found no significant difference in risk of revision between stemmed and stemless total shoulder arthroplasties after adjusting for the type of glenoid component. We advocate that metal-backed glenoid components should be used with caution and not on a routine basis.
KW - all-polyethylene glenoid component
KW - Anatomic total shoulder arthroplasty
KW - glenoid fixation
KW - Level III
KW - metal-backed glenoid component
KW - registry study
KW - Retrospective Cohort Comparison Using Large Databases
KW - stemless total shoulder arthroplasty
KW - stemmed total shoulder arthroplasty
KW - Treatment Study
UR - http://www.scopus.com/inward/record.url?scp=85199049668&partnerID=8YFLogxK
U2 - 10.1016/j.jse.2024.03.022
DO - 10.1016/j.jse.2024.03.022
M3 - Article
C2 - 38685378
AN - SCOPUS:85199049668
SN - 1058-2746
JO - Journal of Shoulder and Elbow Surgery
JF - Journal of Shoulder and Elbow Surgery
ER -