TY - JOUR
T1 - Correlation of atrial electrocardiographic amplitude with radiofrequency energy required to ablate cavotricuspid isthmus-dependent atrial flutter
AU - Rotter, Martin
AU - Scavée, Christophe
AU - Sacher, Fréderic
AU - Sanders, Prashanthan
AU - Takahashi, Yoshihide
AU - Hsu, Li Fern
AU - Rostock, Thomas
AU - Hocini, Mélèze
AU - Jaïs, Pierre
AU - Clementy, Jacques
AU - Haïssaguerre, Michel
N1 - Funding Information:
Dr. Rotter is supported by the Swiss National Foundation for Scientific Research, Bern, Switzerland. Dr. Sanders is supported by the Neil Hamilton Fairley Fellowship from the National Health and Medical Research Council of Australia and the Ralph Reader Fellowship from the National Heart Foundation of Australia. Dr. Rostock is supported by the German Cardiac Society.
PY - 2005/3
Y1 - 2005/3
N2 - Objectives: The purpose of this study was to evaluate a possible correlation between atrial ECG amplitude in common atrial flutter (AFL) and radiofrequency (RF) energy required to achieve cavotricuspid isthmus block. Background: The amount of RF delivery required for ablation of typical AFL is variable. This variation has been attributed to the cavotricuspid isthmus anatomy. Atrial ECG amplitude can be a marker of atrial anatomic variations and therefore may correlate with RF duration required to achieve cavotricuspid isthmus block. Methods: Seventy consecutive patients were prospectively studied. Ablation of the cavotricuspid isthmus was performed by creating a line of block between the inferior tricuspid annulus and the inferior caval vein using 8-mm-tip electrode catheters. If more than 20 minutes of RF time was required to achieve conduction block, the catheter was changed to an irrigated-tip catheter. Atrial ECG amplitude was assessed in leads II, III, aVF, and aVL. Results: A total of 14 ± 11 minutes of RF energy was delivered to achieve block in all patients; 12 patients (8%) required more than 20 minutes. Atrial ECG amplitude showed highly significant correlations with cumulative RF energy (F and P waves in lead II: r = 0.703 and r = 0.737, P < .001). P-wave amplitude <0.2 mV and/or flutter wave amplitude <0.35 mV in lead II have a high negative predictive value to predict <20 min RF delivery (96% and 89% respectively). Conclusions: A significant correlation exists between atrial ECG amplitude and amount of RF required to ablate typical AFL. Atrial ECG amplitude may be a surrogate marker of characteristics of isthmus anatomy. These findings may influence the choice of catheter used for cavotricuspid isthmus ablation.
AB - Objectives: The purpose of this study was to evaluate a possible correlation between atrial ECG amplitude in common atrial flutter (AFL) and radiofrequency (RF) energy required to achieve cavotricuspid isthmus block. Background: The amount of RF delivery required for ablation of typical AFL is variable. This variation has been attributed to the cavotricuspid isthmus anatomy. Atrial ECG amplitude can be a marker of atrial anatomic variations and therefore may correlate with RF duration required to achieve cavotricuspid isthmus block. Methods: Seventy consecutive patients were prospectively studied. Ablation of the cavotricuspid isthmus was performed by creating a line of block between the inferior tricuspid annulus and the inferior caval vein using 8-mm-tip electrode catheters. If more than 20 minutes of RF time was required to achieve conduction block, the catheter was changed to an irrigated-tip catheter. Atrial ECG amplitude was assessed in leads II, III, aVF, and aVL. Results: A total of 14 ± 11 minutes of RF energy was delivered to achieve block in all patients; 12 patients (8%) required more than 20 minutes. Atrial ECG amplitude showed highly significant correlations with cumulative RF energy (F and P waves in lead II: r = 0.703 and r = 0.737, P < .001). P-wave amplitude <0.2 mV and/or flutter wave amplitude <0.35 mV in lead II have a high negative predictive value to predict <20 min RF delivery (96% and 89% respectively). Conclusions: A significant correlation exists between atrial ECG amplitude and amount of RF required to ablate typical AFL. Atrial ECG amplitude may be a surrogate marker of characteristics of isthmus anatomy. These findings may influence the choice of catheter used for cavotricuspid isthmus ablation.
KW - Ablation
KW - Atrial flutter
KW - Electrocardiography
KW - Tachyarrhythmia
UR - http://www.scopus.com/inward/record.url?scp=20044375366&partnerID=8YFLogxK
U2 - 10.1016/j.hrthm.2004.12.018
DO - 10.1016/j.hrthm.2004.12.018
M3 - Article
C2 - 15851316
AN - SCOPUS:20044375366
VL - 2
SP - 263
EP - 269
JO - Heart Rhythm
JF - Heart Rhythm
SN - 1547-5271
IS - 3
ER -