Determination of human absorbed dose of 201Tl(III)-DTPA-HIgG based on biodistribution data in rats

Alireza Khorrami Moghaddam, Amir Reza Jalilian, Vali Hayati, Saeed Shanehsazzadeh

Research output: Contribution to journalArticlepeer-review

14 Citations (Scopus)

Abstract

To estimate the absorbed dose in normal organs and inflammated tissue following i.v. administration of [201Tl](III)-DTPA-HIgG by using biodistribution data in inflammation-bearing rats was attempted. The percentages of injected dose per gram of each organ were calculated. The medical internal radiation dose formulation was applied to calculate the absorbed dose for various organs. The inflammated tissue to blood activity concentration ratios were about 19 and 23.3 at 24 and 28 h post-injection, respectively. A 185-MBq injection of 201Tl-DTPA-HIgG into the human body, might result in an estimated absorbed dose of 14.4 mGy for the total body and the highest absorbed dose was in the kidney with 1195 (mGy) and second to the Spleen were the liver, the lungs and the adrenals, which received 250.5 (mGy), 58.64 (mGy) and 56.44 (mGy), respectively. Biodistribution of [201Tl](III)-DTPA-HIgG demonstrated significant inflammated tissue uptake and low muscle and blood uptake, allowing for imaging of inflammated tissues.

Original languageEnglish
Article numberncq172
Pages (from-to)269-274
Number of pages6
JournalRadiation Protection Dosimetry
Volume141
Issue number3
DOIs
Publication statusPublished or Issued - 16 Jun 2010
Externally publishedYes

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health
  • Radiation
  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Cite this