Development and validation of automated endocardial and epicardial contour detection for MRI volumetric and wall motion analysis

E. G. Caiani, A. Redaelli, O. Parodi, E. Votta, F. Maffessanti, E. Tripoliti, G. Nucifora, D. De Marchi, G. Tarroni, M. Lombardi, C. Corsi

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

2 Citations (Scopus)

Abstract

Dynamic, ECG-gated, steady-state free precession short-axis images were obtained (GE Healthcare, 1.5T) in 8-12 slices in 15 patients with previous myocardia infarction. An expert cardiologist provided the reference values for: 1) left ventricular (LV) volumes and mass, by manually tracing endo and epicardial contours; 2 regional wall motion (WM) interpretation, by grading (normal, abnormal) three slices selected at apical, mid and basal level. Custom software based on image noise distribution and on image gradient was applied, from which end-diastolic (ED) and end-systolic (ES) volumes and mass were computed, as well as regional fractiona area change (RFAC), from which automated classification of regional WM abnormality was defined. Comparison with reference values was performed by: 1) linear regression and Bland-Altman analyses for LV volumes and mass; 2) levels of agreement between the cardiologist WM grades and the automated classification. Optimal correlations (r2>.97) and no bias were found for ED and ES volumes, while LV mass resulted in a good correlation (ED: r2=.81; ES: r 2=.74) with a minimal overestimation (ED: 15.2g; ES: 8.7g) and narrow 95% limits of agreement (ED: ±30g; ES: ±33g). The automated interpretation resulted in high sensitivity, specificity, and accuracy (78%, 85%, 82%, respectively) of WM abnormalities. Combined automated endo and epicardial border detection from MRI images provides reliable measurements of LV dimensions and regional WM classification.

Original languageEnglish
Title of host publicationComputing in Cardiology 2010, CinC 2010
Pages1083-1086
Number of pages4
Publication statusPublished or Issued - 2010
Externally publishedYes
EventComputing in Cardiology 2010, CinC 2010 - Belfast, United Kingdom
Duration: 26 Sept 201029 Sept 2010

Publication series

NameComputing in Cardiology
Volume37
ISSN (Print)2325-8861
ISSN (Electronic)2325-887X

Other

OtherComputing in Cardiology 2010, CinC 2010
Country/TerritoryUnited Kingdom
CityBelfast
Period26/09/1029/09/10

ASJC Scopus subject areas

  • Computer Science(all)
  • Cardiology and Cardiovascular Medicine

Cite this