TY - GEN
T1 - Globally optimal deformable registration on a minimum spanning tree using dense displacement sampling
AU - Heinrich, Mattias P.
AU - Jenkinson, Mark
AU - Brady, Sir Michael
AU - Schnabel, Julia A.
N1 - Publisher Copyright:
© Springer-Verlag Berlin Heidelberg 2012.
PY - 2012
Y1 - 2012
N2 - Deformable image registration poses a highly non-convex optimisation problem. Conventionally, medical image registration techniques rely on continuous optimisation, which is prone to local minima. Recent advances in the mathematics and new programming methods enable these disadvantages to be overcome using discrete optimisation. In this paper, we present a new technique deeds, which employs a discrete dense displacement sampling for the deformable registration of high resolution CT volumes. The image grid is represented as a minimum spanning tree. Given these constraints a global optimum of the cost function can be found efficiently using dynamic programming, which enforces the smoothness of the deformations. Experimental results demonstrate the advantages of deeds: the registration error for the challenging registration of inhale and exhale pulmonary CT scans is significantly lower than for two state-of-the-art registration techniques, especially in the presence of large deformations and sliding motion at lung surfaces.
AB - Deformable image registration poses a highly non-convex optimisation problem. Conventionally, medical image registration techniques rely on continuous optimisation, which is prone to local minima. Recent advances in the mathematics and new programming methods enable these disadvantages to be overcome using discrete optimisation. In this paper, we present a new technique deeds, which employs a discrete dense displacement sampling for the deformable registration of high resolution CT volumes. The image grid is represented as a minimum spanning tree. Given these constraints a global optimum of the cost function can be found efficiently using dynamic programming, which enforces the smoothness of the deformations. Experimental results demonstrate the advantages of deeds: the registration error for the challenging registration of inhale and exhale pulmonary CT scans is significantly lower than for two state-of-the-art registration techniques, especially in the presence of large deformations and sliding motion at lung surfaces.
UR - https://www.scopus.com/pages/publications/84872938499
U2 - 10.1007/978-3-642-33454-2_15
DO - 10.1007/978-3-642-33454-2_15
M3 - Conference contribution
C2 - 23286121
AN - SCOPUS:84872938499
SN - 9783642334535
T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
SP - 115
EP - 122
BT - Medical Image Computing and Computer-Assisted Intervention, MICCAI2012 - 15th International Conference, Proceedings
A2 - Ayache, Nicholas
A2 - Delingette, Herve
A2 - Golland, Polina
A2 - Mori, Kensaku
PB - Springer Verlag
T2 - 15th International Conference on Medical Image Computing and Computer Assisted Intervention, MICCAI 2012
Y2 - 1 October 2012 through 5 October 2012
ER -