N2 - BACKGROUND: It has been hypothesized that internal tocodynamometry, as compared with external monitoring, may provide a more accurate assessment of contractions and thus improve the ability to adjust the dose of oxytocin effectively, resulting in fewer operative deliveries and less fetal distress. However, few data are available to test this hypothesis. METHODS: We performed a randomized, controlled trial in six hospitals in the Netherlands to compare internal tocodynamometry with external monitoring of uterine activity in women for whom induced or augmented labor was required. The primary outcome was the rate of operative deliveries, including both cesarean sections and instrumented vaginal deliveries. Secondary outcomes included the use of antibiotics during labor, time from randomization to delivery, and adverse neonatal outcomes (defined as any of the following: an Apgar score at 5 minutes of less than 7, umbilical-artery pH of less than 7.05, and neonatal hospital stay of longer than 48 hours). RESULTS: We randomly assigned 1456 women to either internal tocodynamometry (734) or external monitoring (722). The operative-delivery rate was 31.3% in the internaltocodynamometry group and 29.6% in the external-monitoring group (relative risk with internal monitoring, 1.1; 95% confidence interval [CI], 0.91 to 1.2). Secondary outcomes did not differ significantly between the two groups. The rate of adverse neonatal outcomes was 14.3% with internal monitoring and 15.0% with external monitoring (relative risk, 0.95; 95% CI, 0.74 to 1.2). No serious adverse events associated with use of the intrauterine pressure catheter were reported. CONCLUSIONS: Internal tocodynamometry during induced or augmented labor, as compared with external monitoring, did not significantly reduce the rate of operative deliveries or of adverse neonatal outcomes. (Current Controlled Trials number, ISRCTN13667534; Netherlands Trial number, NTR285.)
AB - BACKGROUND: It has been hypothesized that internal tocodynamometry, as compared with external monitoring, may provide a more accurate assessment of contractions and thus improve the ability to adjust the dose of oxytocin effectively, resulting in fewer operative deliveries and less fetal distress. However, few data are available to test this hypothesis. METHODS: We performed a randomized, controlled trial in six hospitals in the Netherlands to compare internal tocodynamometry with external monitoring of uterine activity in women for whom induced or augmented labor was required. The primary outcome was the rate of operative deliveries, including both cesarean sections and instrumented vaginal deliveries. Secondary outcomes included the use of antibiotics during labor, time from randomization to delivery, and adverse neonatal outcomes (defined as any of the following: an Apgar score at 5 minutes of less than 7, umbilical-artery pH of less than 7.05, and neonatal hospital stay of longer than 48 hours). RESULTS: We randomly assigned 1456 women to either internal tocodynamometry (734) or external monitoring (722). The operative-delivery rate was 31.3% in the internaltocodynamometry group and 29.6% in the external-monitoring group (relative risk with internal monitoring, 1.1; 95% confidence interval [CI], 0.91 to 1.2). Secondary outcomes did not differ significantly between the two groups. The rate of adverse neonatal outcomes was 14.3% with internal monitoring and 15.0% with external monitoring (relative risk, 0.95; 95% CI, 0.74 to 1.2). No serious adverse events associated with use of the intrauterine pressure catheter were reported. CONCLUSIONS: Internal tocodynamometry during induced or augmented labor, as compared with external monitoring, did not significantly reduce the rate of operative deliveries or of adverse neonatal outcomes. (Current Controlled Trials number, ISRCTN13667534; Netherlands Trial number, NTR285.)
UR - http://www.scopus.com/inward/record.url?scp=75449115144&partnerID=8YFLogxK
U2 - 10.1056/NEJMoa0902748
DO - 10.1056/NEJMoa0902748
M3 - Article
C2 - 20107216
AN - SCOPUS:75449115144
SN - 0028-4793
VL - 362
SP - 306
EP - 313
JO - New England Journal of Medicine
JF - New England Journal of Medicine
IS - 4
ER -