TY - JOUR
T1 - Rehospitalizations for complications and mortality following pacemaker implantation
T2 - A retrospective cohort study in an older population
AU - Gillam, Marianne H.
AU - Pratt, Nicole L.
AU - Inacio, Maria C.S.
AU - Shakib, Sepehr
AU - Sanders, Prashanthan
AU - Lau, Dennis H.
AU - Roughead, Elizabeth E.
N1 - Publisher Copyright:
© 2018 Wiley Periodicals, Inc.
PY - 2018/11
Y1 - 2018/11
N2 - Introduction: A large number of older people receive pacemakers each year but broad population-based studies that describe complications following pacemaker implantation in this population are lacking. Methods: We conducted a retrospective cohort study using data from the Australian Government Department of Veterans' Affairs database. The cohort consisted of patients who received a pacemaker from 2005 to 2014. The outcomes were subsequent rehospitalizations for infections, procedure-related complications, thromboembolism, cardiovascular events (heart failure, myocardial infarction, and atrial fibrillation), and reoperation of pacemaker, and mortality. Results: There were 10 883 pacemakers recipients, the median age was 86 years (interquartile range 83-89), 61% were males, and 74% received a dual-chamber pacemaker. Within 90 days postdischarge, rehospitalizations were occasioned by pacemaker infection in 0.5%, device-related complications in 1.5%, cerebral infarction in 0.7%, and heart failure in 6% of single-chamber pacemaker recipients. In dual-chamber pacemaker recipients rehospitalizations were occasioned by pacemaker infection in 0.4%, septicemia in 0.4%, device-related complications in 1.2%, cerebral infarction in 0.3%, and heart failure in 3%. Rehospitalizations for pacemaker adjustment occurred in 1.5% of patients. The 90-day postdischarge mortality was 5% and 3% in patients with single- and dual-chamber pacemaker, respectively. Conclusion: Rehospitalizations for infection, procedure-related complications, or thromboembolism occurred in 1% to 2% of patients within 90 days postdischarge, while 10% of single chamber and 7% of dual-chamber recipients experienced a rehospitalization for a cardiovascular event.
AB - Introduction: A large number of older people receive pacemakers each year but broad population-based studies that describe complications following pacemaker implantation in this population are lacking. Methods: We conducted a retrospective cohort study using data from the Australian Government Department of Veterans' Affairs database. The cohort consisted of patients who received a pacemaker from 2005 to 2014. The outcomes were subsequent rehospitalizations for infections, procedure-related complications, thromboembolism, cardiovascular events (heart failure, myocardial infarction, and atrial fibrillation), and reoperation of pacemaker, and mortality. Results: There were 10 883 pacemakers recipients, the median age was 86 years (interquartile range 83-89), 61% were males, and 74% received a dual-chamber pacemaker. Within 90 days postdischarge, rehospitalizations were occasioned by pacemaker infection in 0.5%, device-related complications in 1.5%, cerebral infarction in 0.7%, and heart failure in 6% of single-chamber pacemaker recipients. In dual-chamber pacemaker recipients rehospitalizations were occasioned by pacemaker infection in 0.4%, septicemia in 0.4%, device-related complications in 1.2%, cerebral infarction in 0.3%, and heart failure in 3%. Rehospitalizations for pacemaker adjustment occurred in 1.5% of patients. The 90-day postdischarge mortality was 5% and 3% in patients with single- and dual-chamber pacemaker, respectively. Conclusion: Rehospitalizations for infection, procedure-related complications, or thromboembolism occurred in 1% to 2% of patients within 90 days postdischarge, while 10% of single chamber and 7% of dual-chamber recipients experienced a rehospitalization for a cardiovascular event.
KW - complications
KW - mortality
KW - older population
KW - pacemaker implantation
KW - rehospitalization
UR - http://www.scopus.com/inward/record.url?scp=85055285193&partnerID=8YFLogxK
U2 - 10.1002/clc.23091
DO - 10.1002/clc.23091
M3 - Article
C2 - 30294784
AN - SCOPUS:85055285193
SN - 0160-9289
VL - 41
SP - 1480
EP - 1486
JO - Clinical Cardiology
JF - Clinical Cardiology
IS - 11
ER -