TY - JOUR
T1 - Self-Limiting Mussel Inspired Thin Antifouling Coating with Broad-Spectrum Resistance to Biofilm Formation to Prevent Catheter-Associated Infection in Mouse and Porcine Models
AU - Yu, Kai
AU - Alzahrani, Amal
AU - Khoddami, Sara
AU - Ferreira, Demian
AU - Scotland, Kymora B.
AU - Cheng, John T.J.
AU - Yazdani-Ahmadabadi, Hossein
AU - Mei, Yan
AU - Gill, Arshdeep
AU - Takeuchi, Lily E.
AU - Yeung, Edbert
AU - Grecov, Dana
AU - Hancock, Robert E.W.
AU - Chew, Ben H.
AU - Lange, Dirk
AU - Kizhakkedathu, Jayachandran N.
N1 - Publisher Copyright:
© 2021 Wiley-VCH GmbH
PY - 2021/3/17
Y1 - 2021/3/17
N2 - Catheter-associated urinary tract infections (CAUTIs) are one of the most commonly occurring hospital-acquired infections. Current coating strategies to prevent catheter-associated biofilm formation are limited by their poor long-term efficiency and limited applicability to diverse materials. Here, the authors report a highly effective non-fouling coating with long-term biofilm prevention activity and is applicable to diverse catheters. The thin coating is lubricous, stable, highly uniform, and shows broad spectrum prevention of biofilm formation of nine different bacterial strains and prevents the migration of bacteria on catheter surface. The coating method is adapted to human-sized catheters (both intraluminal and extraluminal) and demonstrates long-term biofilm prevention activity over 30 days in challenging conditions. The coated catheters are tested in a mouse CAUTI model and demonstrate high efficiency in preventing bacterial colonization of both Gram-positive and Gram-negative bacteria. Furthermore, the coated human-sized Foley catheters are evaluated in a porcine CAUTI model and show consistent efficiency in reducing biofilm formation by Escherichia coli (E. coli) over 95%. The simplicity of the coating method, the ability to apply this coating on diverse materials, and the high efficiency in preventing bacterial adhesion increase the potential of this method for the development of next generation infection resistant medical devices.
AB - Catheter-associated urinary tract infections (CAUTIs) are one of the most commonly occurring hospital-acquired infections. Current coating strategies to prevent catheter-associated biofilm formation are limited by their poor long-term efficiency and limited applicability to diverse materials. Here, the authors report a highly effective non-fouling coating with long-term biofilm prevention activity and is applicable to diverse catheters. The thin coating is lubricous, stable, highly uniform, and shows broad spectrum prevention of biofilm formation of nine different bacterial strains and prevents the migration of bacteria on catheter surface. The coating method is adapted to human-sized catheters (both intraluminal and extraluminal) and demonstrates long-term biofilm prevention activity over 30 days in challenging conditions. The coated catheters are tested in a mouse CAUTI model and demonstrate high efficiency in preventing bacterial colonization of both Gram-positive and Gram-negative bacteria. Furthermore, the coated human-sized Foley catheters are evaluated in a porcine CAUTI model and show consistent efficiency in reducing biofilm formation by Escherichia coli (E. coli) over 95%. The simplicity of the coating method, the ability to apply this coating on diverse materials, and the high efficiency in preventing bacterial adhesion increase the potential of this method for the development of next generation infection resistant medical devices.
KW - animal models of infection
KW - antifouling coating
KW - catheter-associated urinary tract infection
KW - infection resistant surfaces
KW - long-term biofilm prevention activity
UR - https://www.scopus.com/pages/publications/85100108238
U2 - 10.1002/adhm.202001573
DO - 10.1002/adhm.202001573
M3 - Article
C2 - 33470545
AN - SCOPUS:85100108238
SN - 2192-2640
VL - 10
JO - Advanced Healthcare Materials
JF - Advanced Healthcare Materials
IS - 6
M1 - 2001573
ER -